Characteristics of PV module at standard test condition (STC)
- The STC means the modules are tested at solar irradiance 1000 W/m^2, cell effective temperature 25 degree celcius and air mass 1.5.
- Definition of cell, module, string and array:
- Combinations of cells form a module.
- Module connected in series form a string.
- Series and parallel modules form an array.
- Every PV module has datasheet that describe its electrical properties.
- Example
- The maximum output or peak or rated power of the module (Pmax) = 170 W.
- The manufacturer tolerance of the output power is +/-3%. So for STP 170S-24/Ab-1. PV module the output power could be between 1.03 x 170 W to 0.97 x 170 W. However, in practice most of the PV modules are having negative percentage of power tolerance. So, during design stage we use negative percentage for worst case scenario.
- During peak power condition, the voltage and current of the module are Vmp and Imp respectively.
- During no load condition or open circuit, the voltage of the module is Voc.
- Short circuit current of the module is Isc.